Wire Calculators & Gauge Tools

Professional wire and electrical calculation tools · wire weight, ring weight, SWG / AWG / mm conversion, Ohm's law, RC filters, electrical specs, motor winding, coil length, spring design, tensile strength and reference tables. Built for buyers, engineers and makers.

📱 Use the calculator offline on your Android phone. ⬇ Download APK

Calculate the weight of a wire coil or straight length. Useful for estimating material cost, freight weight and stock requirements.

Result
·
HOW IT WORKS

Weight = p · (d/2)· · Length · Density

Where d = diameter in cm, Length in cm, Density in g/cm·. Result in grams, converted to kg.

MATERIAL DENSITIES
Copper (ETP)8.89 g/cm·
Aluminium (EC)2.70 g/cm·
GI / Mild Steel7.85 g/cm·
SS 3047.93 g/cm·
SS 3167.99 g/cm·
NEED WIRE?

Once you have your weight estimate, request a quote with that quantity.

Request a Quote ?

Calculate the total weight of a batch of wire rings (jump rings). Used for chainmaille, filter rings, OEM parts costing and packing.

Inside dimension of ring
Results
Wire per ring
·
Weight per ring
·
Total wire length
·
Total batch weight
·
FORMULA USED

Wire circumference per ring = p · (Inner Diameter + Wire Diameter)
Volume per ring = p · (Wire Diameter / 2)· · Wire Circumference
Weight per ring = Volume · Density

Note: This is the mean-diameter formula (standard for jump ring calculations). Actual weight may vary ·2% due to cut waste and material tolerances.

ASPECT RATIO
·

AR = Inner Diameter · Wire Diameter. Typical chainmaille AR: 3.5·6.0. Industrial rings: 3·15.

ORDER RINGS

We make rings to your spec · material, gauge, ID, quantity. Open or closed.

Enquire About Rings ?

Enter any gauge or diameter and instantly convert between all three systems. Used for matching international wire specifications to Indian standards.

Conversion Result
SWG
·
AWG
·
DIAMETER (mm)
·
DIAMETER (inch)
·
Cross-section area
·
Closest standard
·
ABOUT WIRE GAUGE SYSTEMS
SWG (Standard Wire Gauge) · British/Indian standard. Higher number = thinner wire. SWG 0 = 8.23mm; SWG 36 = 0.193mm.
AWG (American Wire Gauge) · US standard. Higher number = thinner wire. AWG 0 = 8.25mm; AWG 36 = 0.127mm.
Metric (mm) · Diameter in millimetres. Used in IS, IEC and most modern European standards.
QUICK REFERENCE
SWGmmAWG·

* Weights calculated using standard densities: Copper 8.89 g/cm·, Aluminium 2.70 g/cm·, GI/Steel 7.85 g/cm·. Actual values may vary slightly by temper and alloy. All data for guidance only.

Enter any two values below and leave the other two blank. The solver fills in the missing values using V = I·R and P = V·I.

·
Enter any two values to solve.
FORMULAS

V = I × R
P = V × I = I²R = V² / R
R = V / I = P / I² = V² / P

All values are converted to base units (V, A, Ω, W) before solving.

TIP

Use this to size a supply, check a load current, or verify a resistor's power rating. Allow headroom above the calculated wattage.

Find the −3 dB corner frequency of an RC network, or solve for the resistor or capacitor needed for a target frequency.

Result
·
HOW IT WORKS

fc = 1 / (2πRC)
τ = R × C

At fc the output is 70.7% of the input (−3 dB). For a low-pass RC, attenuation above fc is −20 dB/decade.

PRACTICAL NOTE

Account for capacitor tolerance and source impedance. Real filters often need a margin of 20–50%.

Estimate load current, cable resistance, voltage drop, power loss and the minimum conductor size for a target drop.

·
Load current
·
Loop resistance
·
Power loss
·
Min. size for target drop
·
HOW IT WORKS

I = P / (V × pf) for single-phase
I = P / (√3 × V × pf) for three-phase
R = ρL / A per conductor
DC / 1ph: ΔV = I × 2R, loss = I² × 2R
3ph: ΔV = √3 × I × R, loss = 3I²R

A two-way (loop) path is used for DC and single-phase; balanced three-phase uses the √3 line-drop relation. Reactance and temperature are excluded.

INDICATIVE ONLY

Temperature, installation method, grouping and harmonics are not included. Verify against the applicable wiring standard before installation.

Indicative winding turns, conductor size and slot fill for a three-phase induction motor, using the emf equation and slot geometry.

·
turns per phase (approx.)
Synchronous speed
·
Flux per pole
·
Conductors / slot
·
Turns / coil (double layer)
·
Conductor diameter
·
Closest gauge
·
Current density
·
Slot pitch
·
Phase voltage
·
HOW IT WORKS

Ns = 120f / P
Φ = B × πDL / P
Tph = Vphase / (4.44 f Φ Kw)
Conductors/slot = 6 × Tph / slots

For star, Vphase = Vline / √3; for delta, Vphase = Vline. Double-layer winding assumed. Slot copper area = slot width × depth × fill factor.

DESIGN CHECK

Typical current density is 2–5 A/mm² for small motors. Keep slot copper fill near 0.35–0.45. Final winding design needs magnetic and thermal verification.

Wire length, resistance and weight for a close-wound or pitched solenoid coil.

·
total wire required (including leads)
Mean turn diameter
·
Length per turn
·
Coil height
·
DC resistance
·
Wire weight
·
HOW IT WORKS

Dm = inner dia + wire dia
Turn length = √((π·Dm)² + pitch²)
Total = turns × turn length + leads

Resistance uses ρ at 20 °C. Weight uses the metal density, ignoring insulation.

NOTE

Multi-layer coils need the mean diameter of each layer summed separately. This tool models a single-layer solenoid.

Compression spring rate, deflection, solid height and Wahl-corrected shear stress.

·
spring rate (N/mm)
Spring index (C)
·
Deflection at load
·
Solid height
·
Usable deflection
·
Load at solid
·
Shear stress (Wahl)
·
HOW IT WORKS

C = D / d
k = G·d⁴ / (8·D³·n)
δ = F / k
Kw = (4C−1)/(4C−4) + 0.615/C
τ = Kw · 8FD / (πd³)

Closed and ground ends assumed: total coils = active + 2.

DESIGN CHECK

A spring index between 4 and 12 is generally preferred. Leave clearance to solid height and check fatigue life for cyclic loads.

Convert a break load into tensile strength, check working stress and safety factor, and find allowable load for a chosen factor.

·
ultimate tensile strength (MPa)
Cross-section area
·
Working stress
·
Actual safety factor
·
Allowable working load
·
HOW IT WORKS

A = πd² / 4
UTS = F_break / A
Safety factor = F_break / F_work
Allowable load = F_break / required SF

1 N/mm² = 1 MPa; 1 kgf = 9.80665 N.

TEST DATA MATTERS

Use an actual tensile test result for the specific temper and alloy. Catalogue values are indicative only.

Wire Specification Reference Guide

Everything buyers, engineers and makers need to specify wire correctly the first time.

📏

SWG (Standard Wire Gauge) is the system used in India and the UK · IS and BS standards reference SWG numbers. AWG is the American standard used in ASTM, UL and NEC specifications. When sourcing wire internationally or reading foreign datasheets, always confirm which gauge system applies before ordering.

⚖️

Accurate weight estimation is essential for freight planning, cost estimation and inventory management. Use our Wire Weight Calculator to determine coil weight before requesting a quote · we can then confirm pricing per kg or per coil for your specific gauge and material.

🔄

Aspect Ratio (AR) = Inner Diameter · Wire Diameter. For chainmaille, AR determines which weaves are achievable. Box chain: AR ~3.0·3.5. Full Persian: AR ~3.7·4.2. For industrial filter rings, higher AR gives larger flow aperture per ring. Our ring calculator outputs AR automatically.

Need Wire to the Right Specification?

Now that you have the weight and gauge right, let us quote the material. We supply across India with mill certificates on request.